Table 2. Main parameters of multichannel instrument systems for submarines.
Table 2. Main parameters of multichannel instrument systems for submarines
Country, company |
Model |
D, km |
2w, deg. |
2W, deg. |
Dl, µm |
FPU type, number of pixels |
Weight, kg |
Dimensions, mm |
Note |
|
Germany, Zeiss Optronik GmbH | OMS 100 | 0.13 – 3.3 (3) | 12.4×9 (1); 4.1×3, 1 (1); 23.6×13.4 (2); 3×1.7(2) |
360 (H); 15…+60 (V) |
3 – 5 (1) or 8 – 12 (1); 1.54 (3) |
KRT (1), 320×240 ; CCD (2), 1920×1080 | 340 | 380×2025 | tр = – 35…+600 C (outboard part of the complex); tр = 0…+550 C (side part of the complex) |
|
— “- |
SERO 400 |
-“- |
36×28 (3) (G = 15x); 8×6.5 (3) (G = 6x); 4.2×3.4 (3) (G = 12x) |
-“- | 0.4 – 0.9 (3); 1.543 (4) |
CCD (3), 752×582 | 11000 – periscope length, 190.5 – its diameter, 610 – eyepiece box diameter | tр = –35…+600 C (outboard part of the complex); tр = 0…+550 C (side part of the complex); Two-axis gyrostabilization, minimum operating illumination for night TV camera 10-4 lux |
||
Great Britain, Barr and Stroud | EONHPM | 7 (3) (H = 6x) |
360 (H); 7.5…+15 (V) |
range measurement accuracy ± 10 m; supply voltage =24 V | ||||||
Israel, Opgal Optronic Industries Ltd. | Submarine Nite Eye | 2.75×1.9 (1); 10.5×6.5 (1) | 8 – 12 (1) | 7 | 160x120x400 | TVP |
Notes to tables 1, 2: Dob/Dras – detection/recognition range; D – operating range; 2w – field of view angle; 2W – viewing angle; Dl – working spectrum region; U – supply voltage; Pe – power consumption; Vсл – tracking speed; асл – tracking acceleration; DT – temperature resolution; Г = nх magnification (times); tр – operating temperature; (РС) – supersonic missiles; (РД) – subsonic missiles; (РБ) – ballistic missiles; (С) airplane; (Вр) – helicopter; (К) – ship; (Г) – horizontal scan; (В) – vertical scan (1) TVP channel; (2) – daytime TV channel; (3) – night TV channel; (4) – laser rangefinder channel; (5) radar channel.