Publications of the journal Special Equipment. The article was updated on 20.04 in 2023.

ik
Publications of the journal Special Equipment.

Product type Purpose Protection method Operational control of proper operation Need for routine maintenance Maintaining operability with active methods of influence Detection during operation of replacement or damage to the SZ All failures that reduce efficient operation are detected during operation. Power supply  Backup power supply operating time (h) Current consumption, mA Note
primary backup
“Korund” Protection of 2-wire
analog TA
PSZ no yes no no no no not required  

 

Certificate available
“Granite-8M”  

 

PSZ no yes not fully no no not required  

 

 

 

 

 

“Bouquet” PSZ no yes -«- no no and  

 

-«-
“Gran-300” 2-wire
analogue protection TA
PSZ no yes not fully  

 

 

 

from subscriber lines  

 

0.1  

 

“MP-1 A” 2-wire protection
analog TT powered from ATS
PSZ + ASZ during dialing no yes yes yes, in terms of ASZ, not fully in terms of PSZ from subscriber line  

 

<0.4  

 

“MP-1 C” Protection of 2-wire
digital telephone with power supply from PBX
PSZ+ ASZ by connecting headphones to the subscriber line no yes no -«- «»  

 

<0,4
“MP-2” Protection of 3-program
receivers
PSZ+ ASZ optical no yes yes yes food 3-program. receiver  

 

<9 Under design certificate
“MP-3” TSPI protection over the network
220V power supply
PSZ not required no Yes no no -220V  

 

 

 

 

 

“MP-4” Secondary clock protection ASZ optical no yes yes TO “Crown” < 0.06  

 

-«-
“MP-5” Loudspeaker protection
of the public address system
PSZ alert signal yes yes yes TO “Krona” < 6  

 

 

 

“MP-6” Universal protection device
of 2-wire analog and digital TA with backup
power supply
PSZ+ ASZ optical monitoring of MP and battery discharge no yes yes yes, in terms of ASZ, not fully in terms of PSZ from subscriber line “Krona” >1260 <0,5  

 

“MP-7” Device with backup power
for protection of 2-wire digital telephones with
loudspeaker communication
PSZ + ASZ  

 

no yes yes  

 

from subscriber line “Krona” > 900 <7 Under development

Passive IR sensors for security alarms

Мы используем cookie-файлы для наилучшего представления нашего сайта. Продолжая использовать этот сайт, вы соглашаетесь с использованием cookie-файлов.
Принять